| Navigation
Light Control Panel
Aqua Signal 3425 (fuses)
3435 (circuit breakers)
Application: All vessels which require navigation lights to be
supervised and monitored with an alarm, switched and fuse or circuit breaker
protected.
Approvals: Lloyd's, ABS, DNV, BV, GL, others on request
Protection class: IP20, (IP23 when fitted with front panel membrane)
Chassis: white powder coated
Front Panel: Natural or mat black anodized, special order wine red (RAL
3005) with yellow (RAL 1018) lettering, ship or signaling mast mimic
Radio interference suppression: "K"
Mounting: cut out for drop in panel into consol on bridge
Description: The purpose of the panel is to switch, monitor and protect
by fuse or circuit breaker each navigation and signal light. The panel
consists of a front plate with switches, indicators, and a chassis attached
to the front plate. The chassis contains circuit boards for monitoring each
light circuit and each voltage input. The light circuits are connected via
twin numbered terminal in the chassis. A wiring diagram is supplied to show
the layout of the terminals. Lights are shown on a mimic of the vessel or
christmas tree.
Operation: Each light circuit is supervised by indirect current
monitoring so there is no electrical connection between the light circuit
and the monitoring circuit. There is no load or voltage drop caused by the
monitoring circuit. With the light switched on proper function of the light
is shown by an illuminated LED or two LED where a ships mimic is displayed.
The brightness of LED can be adjusted but can not be dimmed to zero. If the
lamp circuit is defective, ie. blown fuse, short circuit, open circuit, the
corresponding LED will start flashing and an audible alarm will sound and
will stay on until the alarm is acknowledged. The audible alarm can be
silenced but the LED will continue to flash until corrective action is
taken. All subsequent failures before the first is cleared will again sound
the audible alarm again and have to be acknowledged. The visual signal of
the flashing LED will stay lit for each circuit where a failure is detected
until each circuit is repaired. Failure of the detector circuit does not
affect the operation of the lights. Failure of the main voltage feed will
cause an alarm and the panel will automatically switch to the secondary
supply.
Labelling and engraving: This is to the customers specification and
requirements.
|
Navigation Light Panel
3425202 (fuses)
Navigation Light Panel 3435202 (circuit breakers)

  
Signal Light Panel 3425201 (fuses)
Signal Light Panel 3435201 (circuit breakers)

  
|
|
Other Navigation Light
Panel Configurations
3425205
3425205, 3425206, 3425207, 3459xxx
|
Other Signal Light Panel Configurations
3435203,
3435204
3435205,
3435206, 3435207
|