Quality Marine
Products Distributor

Presents

Aqua Signal
Marine Flood Lights
for hazardous locations

 


Click on any image to see a larger version of the picture
and then use the "Back" button in your browser to return to this page

 Ex n Flood Light
 HPS/MH max 400w
for hazardous areas zone 2
separate ballast required

Aqua Signal   1776001 & 1776002
Application:
Hazardous Areas Zone 2
Design: According to international rules for zone 2, and to IEC 79-15
Approval authority: Physikalisch-Technische Bundesanstalt, Braunschweig, PTB cert no. Ex-97.Y.2602 X
Ignition Class: Ex nR II T3
Protection Class:  IP67
Housing:  Stainless steel, deep drawn seamless
Reflector: Highly polished aluminium, anodized
Diffuser: Safety glass
Finish: Powder coated white RAL 9016, and enameled up to 70 - 80 µm thickness
Electrical: Flexible wiring, Silicone insulated, heat resistant to 180°C, 1 external junction box
Ballast unit: Separate ballast unit is required
Versions:  Narrow (26°) wide (50°)
Mounting:  Adjustable bracket with 4 mounting holes, 10.5/14mm in diameter
Supply voltage:
ballast unit determines the voltage and the lamp
Lamp base:  E40 HPS - high pressure sodium - MH Metal halide 250w or 400w
 
(HPS or MH lamp is not included with the fixture or ballast)


aqua signal 1776001 & 1776002 Ex n floodlightsaqua signal 1776001 & 1776002 Ex n floodlight dimensionsaqua signal 1776001 & 1776002 Ex n floodlight parts drawing
aqua signal 1776001 Ex n floodlight light output graphaqua signal 1776002 Ex n floodlight light output graph
     narrow 26°           wide 50°      

Ex n Flood Light
Halogen max 500w
for hazardous areas zone 2

Aqua Signal   1776073 & 1776074
Application:
Hazardous Areas Zone 2
Design: According to international rules for zone 2, and to IEC 79-15
Approval authority: Physikalisch-Technische Bundesanstalt, Braunschweig, PTB cert no. Ex-97.Y.2602 X
Ignition Class: Ex nR II T3
Protection Class:  IP67
Housing:  Stainless steel, deep drawn seamless
Reflector: Highly polished aluminium, anodized
Diffuser: Safety glass
Finish: Powder coated white RAL 9016, and enameled up to 70 - 80 µm thickness
Electrical: Flexible wiring, Silicone insulated, heat resistant to 180°C, 1 external junction box
Versions:  Narrow (16°) wide (70°)
Mounting:  Adjustable bracket with 4 mounting holes, 10.5/14mm in diameter
Supply voltage:
ballast unit determines the voltage and the lamp
Lamp base:  E40 Halogen lamp 500w
Note: only lamps manufactured by BLV, General Electric or Philips are to be used with this fixture
 
(Halogen lamp is not included with the fixture)


aqua signal 1776073 & 1776074 Ex n floodlight light aqua signal 1776073 & 1776074 Ex n floodlight light dimensionsaqua signal 1776073 & 1776074 Ex n floodlight light  parts drawing
aqua signal 1776073 Ex n floodlight light output graphaqua signal 1776074 Ex n floodlight light output graph
     narrow 16°           wide 70° 

Ex n Flood Light
 HPS/MH - 2 x max. 400w
for hazardous areas zone 2
separate ballast required

Aqua Signal   1776060 & 1776066
Application:
Hazardous Areas Zone 2
Design: According to international rules for zone 2, and to IEC 79-15
Approval authority: Physikalisch-Technische Bundesanstalt, Braunschweig, PTB cert no. Ex-97.Y.2602 X
Ignition Class: Ex nR II T3
Protection Class:  IP67
Housing:  Stainless steel, deep drawn seamless
Reflector: Highly polished aluminium, anodized
Diffuser: Safety glass
Finish: Powder coated white RAL 9016, and enameled up to 70 - 80 µm thickness
Electrical: Flexible wiring, Silicone insulated, heat resistant to 180°C, 2 external junction box each with 1 ignition unit
Ballast unit: Separate ballast unit is required
Versions:  Narrow (26°) wide (50°)
Mounting:  2 Adjustable brackets each with 2 mounting holes, 14mm in diameter
Supply voltage:
ballast unit determines the voltage and the lamp
Lamp base:  E40 HPS - high pressure sodium - MH Metal halide 250w or 400w
 
(HPS or MH lamp is not included with the fixture or ballast)




     narrow 26°           wide 50°   

Ex n Flood Light Ballast
 for hazardous areas zone 2
for HPS/MH light sources

Aqua Signal   1527
Application:
Hazardous Areas Zone 2
Design: According to international rules for zone 2, and to IEC 79-15
Approval authority: Physikalisch-Technische Bundesanstalt, Braunschweig, PTB cert no. Ex-97.Y.2603 X
Ignition Class: Ex nR II T5
Protection Class:  IP67
Housing & lid:  Stainless steel, deep drawn seamless
Finish: Powder coated white RAL 9016, and enameled up to 70 - 80 µm thickness
Electrical: Flexible wiring, Silicone insulated, heat resistant to 105°C,
Versions:  1 x 250w HPS/MH, 2 x 250w HPS/MH, 1 x 400w HPS, 1 x 400w MH, 2 x 400w HPS, 2 x 400w MH
Mounting:  2 welded brackets each with 2 mounting holes, 10.5mm in diameter
Supply voltage: 220v 60Hz, 240v 60Hz, 230v 50Hz, 240v 60Hz
Note: ballast unit determines the voltage and the lamp
 
(HPS or MH lamps are not included with the fixture or ballast)


Ex n Flood Light
HPS/MH max. 400W
for hazardous areas zone 2
with internal ballast

Aqua Signal   1776005  -  1776052
Application:
Hazardous Areas Zone 2
Design: According to international rules for zone 2, and to IEC 79-15
Approval authority: Physikalisch-Technische Bundesanstalt, Braunschweig, PTB cert no. Ex-97.Y.2602 X
Ignition Class: Ex nR II T3
Protection Class:  IP67
Housing:  Stainless steel, deep drawn seamless
Reflector: Highly polished aluminium, anodized
Diffuser: Safety glass
Finish: Powder coated white RAL 9016, and enameled up to 70 - 80 µm thickness
Electrical: Flexible wiring, Silicone insulated, heat resistant to 180°C, 1 external junction box with ignition unit
Ballast unit:
included and contained within the fixture
Versions: narrow (26°) or wide beam (50°)
Mounting:  2 Adjustable brackets each with 2 mounting holes, 14mm in diameter
Supply voltage: 230v 50Hz, 240v 50Hz, 220v 60Hz, or 240v 60Hz with high power factor correction (hpfc) or no power factor correction (lpfc) other voltages on request
Lamp base:  E40  HPS (high pressure sodium) or MH (metal halide) lamps 250w or 400w
 
(HPS lamp is not included with the fixture)




 
    narrow 26°           wide 50°

Jastram  Logo and page style © Jastram  Technologies Ltd.
Aqua Signal Logo, graphics and text © Aqua Signal Gmbh
last updated 11th May 2002