| EEx e
Luminaire, Surface Mount
Aqua Signal 0285
Application: Hazardous areas zone 1 and 2
Ignition Class: EEx e md IIC T5
Approval Authority: Physikalisch-Technische Bundesanstalt
Design: According to the rules of maritime classification societies,
additional VDE and IEC / EN
Protection Class: IP67
Housing: Zinc coated steel sheet, deep drawn seamless
Gear tray: Zinc Coated Steel Sheet powder coated white RAL 9016 and
enameled up to 70-80µm thickness
Diffuser: Clear polycarbonate, reinforced
Electrical: Electronic ballast, flexible wiring, heat resistant to
105°C, through wiring up to 16 amps possible, types with battery backup
system installed; integral NiCad battery with overload protection, LED
indication of battery power,
Emergency operation: 1 x 18/20 watt tube 180 minutes at 45% luminous
intensity; 1 x 36/40 watt tube 180 minutes at 25% luminous intensity;
recharge time from full discharge; 18/20 w 24 hours, 36/40w 36 hours
Mounting: 2 welded brackets with 2 mounting holes each 10.5mm in
diameter
Supply voltage: 230v - 254v 0/50/60hz standard, others on
request
Versions available: 1 x 18/20w; 2 x 18/20w; 1 x 36/40w, & 2 x
36/40w with or without battery backup
Lamp base: G 13 for 2 pin T26 or T38 Fluorescent tubes
(fluorescent tubes are not included with the fixture) |

  
2 x 18/20w
1 x 36/40w 2 x 36/40w
  
|
|
EEx e Luminaire, Surface Mount
Aqua Signal 0278 (without battery
backup)
Aqua Signal 0248 (with battery backup)
Application: Hazardous areas zone 1
and 2
Ignition Class: EEx edq IIC T4
Approval Authority: Physikalisch-Technische Bundesanstalt
Design: According to the rules of maritime classification societies,
additional VDE and IEC / EN
Protection Class: IP67
Housing: Zinc coated steel sheet, deep drawn seamless
Gear tray: Zinc Coated Steel Sheet powder coated white RAL 9016 and
enameled up to 70-80µm thickness
Diffuser: Clear polycarbonate, reinforced
Electrical: 0278 Flexible wiring, heat resistant to 105°C, through
wiring up to 16 amps possible, 0248 flexible wiring, heat resistant
to 105°C, through wiring up to 16 amps possible in 40 watt fixtures only,
integral NiCad battery with ventilation, overload protection, Red LED for
battery power indication,
Emergency operation 0248: 1 x 20w 90 minutes at 40% luminous
intensity, 1 x 40w 60 minutes at 25% luminous intensity, @ +25°C, recharge
of battery from full discharge 24 hours
Mounting: 2 welded brackets with 2 mounting holes each 10.5mm in
diameter
Supply voltage: 110, 127, 220, 240, 254 volts standard, others on
request,
Versions available: 0278/0248 2 x 18/20w; 1 x 36/40w, &
2 x 36/40w; 0278 50/60Hz High Power Factor Correction or low power
factor, 0248 50/60Hz high power factor correction only
Lamp base: FA 6 single pin according to IEC 61-1 for T38
fluorescent tubes 20 or 40 watt
(fluorescent tubes
are not included with the fixture) |
0248 with
battery backup

  
2 x 18/20w
1 x 36/40w 2 x 36/40w
  
0278 with no
battery backup

  
2 x 18/20w
1 x 36/40w 2 x 36/40w
   |
|
Ex n Luminaire, Surface Mount
Aqua Signal 1744
Application: Hazardous areas zone 2
Ignition Class: Ex nA II T4
Approval Authority: Physikalisch-Technische Bundesanstalt
Design: According to the rules of maritime classification societies,
additional VDE and IEC / EN
Protection Class: IP44 / IP67
Housing: Zinc coated steel sheet, deep drawn seamless
Gear tray: Zinc Coated Steel Sheet powder coated white RAL 9016 and
enameled up to 70-80µm thickness
Diffuser: Clear polycarbonate
Electrical: Flexible wiring, heat resistant to 105°C, through wiring up
to 16 amps possible, removable gear tray with plug in connector to housing
Mounting: 2 mounting holes each 10.0mm in diameter
Supply voltage: 230v / 240v 50/60hz high power factor
correction standard, others on request
Versions available: 1 x 18/20w; 2 x 18/20w; 1 x 36/40w, & 2 x
36/40w
Lamp base: G 13 for 2 pin T26 or T38 Fluorescent tubes
(fluorescent tubes are not included with the fixture) |

  
1 x 18/20w
2 x 18/20w
 
1 x 36/40w
2 x 36/40w
  |
|
Ex n Luminaire, Surface Mount
Aqua Signal 0273
Application: Hazardous areas zone 1 and 2
Ignition Class: EEx d IIB T5
Approval Authority: Physikalisch-Technische Bundesanstalt
Design: According to the rules of maritime classification societies,
additional VDE and IEC / EN
Protection Class: IP67
Housing: Stainless steel ends and gear tray
Diffuser: Clear polycarbonate
Electrical: Flexible wiring, heat resistant to 105°C, removable
gear tray
Mounting: with 2 stainless steel or polycarbonate mounting clamps
(clamps must be ordered separately)
Supply voltage: 230v 50z high power factor correction
standard, others on request
Versions available: 1 x 18/w
Lamp base: 2G 11 for TC-L compact fluorescent
(fluorescent tubes are not included with the fixture) |
 
 
1 x 18w
 |
|
Ex n Luminaire, Surface Mount
Aqua Signal 970003
Application: Hazardous areas zone 1 and 2
Ignition Class: EEx de IIB T5
Approval Authority: Physikalisch-Technische Bundesanstalt
PTB cert. no. Ex-91-96.D.1012
Design: According to the rules of maritime classification societies,
additional VDE and IEC / EN
Protection Class: IP65
Housing: Aluminium die-casting, painted grey, sea-water resistant,
Diffuser: Safety Glass pressure tested to 10 bar
Electrical: Flexible wiring, heat resistant to 105°C, removable
gear tray
Mounting: with 2 brackets with 1 mounting hole each 11 x 25mm
Supply voltage: 220v 50z or 60 Hz high power factor correction
standard, others on request
Versions available: 2 x 18/20w, 2 x 36w
Lamp base: G13 for T26 fluorescent tubes 18w or 36w white
(fluorescent tubes are not included with the fixture) |

 
2 x 18/20w
2 x 36/40w
  |