Quality Marine Products Distributor

Presents

Aqua Signal
Marine Lighting
for Hazardous Areas
 

Click on any image to see a larger version of the picture
and then use the "Back" button in your browser to return to this page

EEx e Luminaire, Surface Mount

Aqua Signal 0285
Application:
Hazardous areas zone 1 and 2
Ignition Class: EEx e md IIC T5
Approval Authority: Physikalisch-Technische Bundesanstalt
Design: According to the rules of maritime classification societies, additional VDE and IEC / EN
Protection Class:  IP67
Housing:  Zinc coated steel sheet, deep drawn seamless
Gear tray: Zinc Coated Steel Sheet powder coated white RAL 9016 and enameled up to 70-80m thickness
Diffuser: Clear polycarbonate, reinforced
Electrical: Electronic ballast, flexible wiring, heat resistant to 105C, through wiring up to 16 amps possible, types with battery backup system installed; integral NiCad battery with overload protection, LED indication of battery power,
Emergency operation: 1 x 18/20 watt tube 180 minutes at 45% luminous intensity; 1 x 36/40 watt tube 180 minutes at 25% luminous intensity; recharge time from full discharge; 18/20 w 24 hours, 36/40w 36 hours
Mounting: 2 welded brackets with 2 mounting holes each 10.5mm in diameter
Supply voltage: 230v - 254v  0/50/60hz standard, others on request
Versions available:  1 x 18/20w; 2 x 18/20w; 1 x 36/40w, & 2 x 36/40w with or without battery backup
Lamp base:  G 13 for 2 pin T26 or T38 Fluorescent tubes
(fluorescent tubes are not included with the fixture)





    2 x 18/20w          1 x 36/40w         2 x 36/40w

 

EEx e Luminaire, Surface Mount

Aqua Signal 0278 (without battery backup)
Aqua Signal 0248
(with battery backup)

Application: Hazardous areas zone 1 and 2
Ignition Class: EEx edq IIC T4
Approval Authority: Physikalisch-Technische Bundesanstalt
Design: According to the rules of maritime classification societies, additional VDE and IEC / EN
Protection Class:  IP67
Housing:  Zinc coated steel sheet, deep drawn seamless
Gear tray: Zinc Coated Steel Sheet powder coated white RAL 9016 and enameled up to 70-80m thickness
Diffuser: Clear polycarbonate, reinforced
Electrical: 0278 Flexible wiring, heat resistant to 105C, through wiring up to 16 amps possible, 0248 flexible wiring, heat resistant to 105C, through wiring up to 16 amps possible in 40 watt fixtures only, integral NiCad battery with ventilation, overload protection, Red LED for battery power indication,
Emergency operation 0248: 1 x 20w 90 minutes at 40% luminous intensity, 1 x 40w 60 minutes at 25% luminous intensity, @ +25C, recharge of battery from full discharge 24 hours
Mounting: 2 welded brackets with 2 mounting holes each 10.5mm in diameter
Supply voltage: 110, 127, 220, 240, 254 volts standard, others on request,
Versions available:  0278/0248 2 x 18/20w; 1 x 36/40w, & 2 x 36/40w; 0278 50/60Hz High Power Factor Correction or low power factor, 0248 50/60Hz high power factor correction only
Lamp base:  FA 6 single pin according to IEC 61-1 for T38 fluorescent tubes 20 or 40 watt
(fluorescent tubes are not included with the fixture)

   0248 with battery backup


    2 x 18/20w          1 x 36/40w         2 x 36/40w


   0278 with no battery backup


    2 x 18/20w          1 x 36/40w         2 x 36/40w

Ex n Luminaire, Surface Mount

Aqua Signal 1744
Application:
Hazardous areas zone 2
Ignition Class: Ex nA II T4
Approval Authority: Physikalisch-Technische Bundesanstalt
Design: According to the rules of maritime classification societies, additional VDE and IEC / EN
Protection Class:  IP44 / IP67
Housing:  Zinc coated steel sheet, deep drawn seamless
Gear tray: Zinc Coated Steel Sheet powder coated white RAL 9016 and enameled up to 70-80m thickness
Diffuser: Clear polycarbonate
Electrical:
Flexible wiring, heat resistant to 105C, through wiring up to 16 amps possible, removable gear tray with plug in connector to housing
Mounting: 2 mounting holes each 10.0mm in diameter
Supply voltage: 230v / 240v  50/60hz  high power factor correction standard, others on request
Versions available:  1 x 18/20w; 2 x 18/20w; 1 x 36/40w, & 2 x 36/40w
Lamp base:  G 13 for 2 pin T26 or T38 Fluorescent tubes
(fluorescent tubes are not included with the fixture)




    1 x 18/20w         2 x 18/20w

    1 x 36/40w         2 x 36/40w

Ex n Luminaire, Surface Mount

Aqua Signal 0273
Application:
Hazardous areas zone 1 and 2
Ignition Class: EEx d IIB T5
Approval Authority: Physikalisch-Technische Bundesanstalt
Design: According to the rules of maritime classification societies, additional VDE and IEC / EN
Protection Class:  IP67
Housing:  Stainless steel ends and gear tray
Diffuser: Clear polycarbonate
Electrical: Flexible wiring, heat resistant to 105C,  removable gear tray
Mounting: with 2 stainless steel or polycarbonate mounting clamps (clamps must be ordered separately)
Supply voltage: 230v  50z  high power factor correction standard, others on request
Versions available:  1 x 18/w
Lamp base:  2G 11 for TC-L compact fluorescent
(fluorescent tubes are not included with the fixture)




    1 x 18w

Ex n Luminaire, Surface Mount

Aqua Signal 970003
Application:
Hazardous areas zone 1 and 2
Ignition Class: EEx de IIB T5
Approval Authority: Physikalisch-Technische Bundesanstalt
PTB cert. no. Ex-91-96.D.1012
Design: According to the rules of maritime classification societies, additional VDE and IEC / EN
Protection Class:  IP65
Housing:  Aluminium die-casting, painted grey, sea-water resistant,
Diffuser: Safety Glass pressure tested to 10 bar
Electrical: Flexible wiring, heat resistant to 105C,  removable gear tray
Mounting: with 2 brackets with 1 mounting hole each 11 x 25mm
Supply voltage: 220v  50z or 60 Hz high power factor correction standard, others on request
Versions available:  2 x 18/20w, 2 x 36w
Lamp base:  G13 for T26 fluorescent tubes 18w or 36w white
(fluorescent tubes are not included with the fixture)




    2 x 18/20w         2 x 36/40w